Always keep a 3 stud (3-1/2" - 9 cm) spacing between heating cable runs. All heating cable test results must be recorded in the heating cable tests log in the DITRA-HEAT Installation Guide and a copy of the log submitted with the warranty registration card (by mail or via www.schluter.com/registerwarranty) for warranty purposes. Vapor Management The free space on the underside of DITRA-HEAT provides a route for excess moisture and vapor to escape from the substrate that could otherwise cause damage to the tile covering above. IMPORTANT: HEATING CABLES CANNOT BE CUT TO FIT Never install the heating cable under vanities with no air space beneath, bathtub platforms, free standing bathtubs with no air space beneath, kitchen cabinets or any other fixtures, or in storage or clothing closets. Its polypropylene composition protects the substrate from moisture penetration, which is particularly important in today’s building environment where most substrates are moisture-sensitive. The minimum required tile format for use with DITRA-HEAT is 2" x 2" (50 mm x 50 mm). For complete installation guidelines and warranty criteria, please refer to the downloadable Schluter®-DITRA-HEAT Installation Handbook or to the installation video online. DITRA-HEAT combines the flexibility of loose heating cables with the ease of installation of mat systems. 3. When you need an easy-to-install underfloor heat product for flexible application, ThermoTile Cable is the right solution. Note: Aligning the studs on the top of the matting during installation can help make subsequent heating cable installation easier. It is helpful to plan the location of a buffer zone, as it is not possible to predict where the heating cable will end. The DITRA-HEAT system is unique because the heating cables are easily snapped into place on top of the uncoupling mat with no clips or fasteners. When you use DITRA-HEAT cable with the uncoupling membrane, you get a 4-in-1 layer that supports tile and stone floors with even load distribution, subfloor protection from wetness and humidity via vapor management and waterproofing properties. These dealers accept Project Lists and can help you choose just the right products for your project. Lift up a corner of the matting to check coverage. Apply DITRA-HEAT to the floor, fleece side down. Alternate Floor Coverings over DITRA-HEATDITRA-HEAT is suitable for applications with engineered wood, vinyl, wood plastic composite (WPC), luxury vinyl tiles (LVT), luxury vinyl planks (LVP), stone plastic composite (SPC) tiles and planks, and laminate flooring. This area allows for placement of excess heating cable. • Do not use this r epair kit to splice different heating cables together. Schluter DITRA is an uncoupling mat that’s placed over wood or cement subfloors. Loads are transferred from the tile covering through these column-like mortar structures to the substrate. It is a universal substrate for tile coverings, which serves as an uncoupling layer, bonded waterproofing and moisture vapour barrier and is designed for the attachment of the matching heating cables of the system for floor heating. If full coverage is not achieved, remove and reapply, making sure to verify proper mortar consistency and application. Find the website that's made specifically for you. Cutting the cable will change the resistance and could result in cable damage or fire. The components included in the kit are Ditra-Heat uncoupling membrane, heating cable, and a touchscreen programmable thermostat. DITRA-HEAT twisted pair heating cable is designed to snap into DITRA-HEAT uncoupling membrane (sold separately). Solidly embed the matting into the mortar using a float, screed trowel, or DITRA-ROLLER, making sure to observe the open time of the bonding mortar. Note: Coverage may vary with mortar consistency, angle at which the trowel is held, substrate flatness, etc. Schlüter®-DITRA-HEAT is a polypropylene membrane with a cut back stud structure and an anchoring fleece laminated on the underside. DITRA-HEAT provides uncoupling through its geometric configuration, which allows for in-plane movement that effectively neutralizes the differential movement stresses between the substrate and the tile, thus eliminating the major cause of cracking and delaminating of the tiled surface. No. A narrower spacing may cause a fire or damage the floor covering. DITRA-HEAT uses the same technology and allows heating cables to be run in it’s stud structure. Some limitations include the following: 1- Cushioned vinyl is unacceptable... We don't recommend or warranty DITRA-HEAT installation over existing hardwood flooring as it is very unstable and difficult to bond... Electric radiant floor heating cables used with DITRA-HEAT membrane, Programmable Wi-Fi thermostat for the DITRA-HEAT system, Uncoupling membrane with integrated sound control and thermal break, Programmable touchscreen thermostat for the DITRA-HEAT system, Power module that extends power output for the DITRA-HEAT system, Waterproofing strip seals abutting joints of membranes and building panels, Programmable digital thermostat for the DITRA-HEAT system, Provides electric floor warming for use beneath tile, stone, or other resilient floor coverings (e.g. Support/load distribution When placed on a solid foundation, columns or pillars can support tremendous loads. The DITRA-HEAT system does more than add floor heating. This 120-Volt, 141.1 ft. long cable comes with one temperature sensor. Schluter ®-DITRA-HEAT integrates customizable, comfortable electric floor warming with the functions associated with DITRA: uncoupling, waterproofing, vapor management, and support to ensure a long lasting installation. In order to perform the resistance test, you must set your multimeter for resistance measurement and take an ohms reading between the two power leads (120V power leads are black & yellow / 240V are black & red). Be sure to measure the heated area accurately. Note: Tile can be installed directly over the DITRA-HEAT membrane immediately after the Schluter®-DITRA-HEAT-E-HK cables have been installed using an unmodified thin set. Ditra-Heat Non-Programmable Thermostat, Bright White DITRA-HEAT-E-R is a non-programmable digital DITRA-HEAT-E-R is a non-programmable digital thermostat used to control the DITRA-HEAT-E-HK heating cables (either 120-Volt or 240-Volt). The DITRA-HEAT-E-HK heating cables can now be installed. The buffer zone is an area where heating is not essential, typically behind a toilet or adjacent to a door opening. Use our DITRA-HEAT calculator to find out what products you need to complete your specific installation. Installing Heating Cable and Schluter ® DITRA-HEAT Uncoupling Membrane Using a thin-set mortar that is suitable for the substrate, apply the thin-set mortar (mixed to a fairly fluid consistency, but still able to hold a notch) using a 1/4" x 1/4" square-notched trowel. the Schluter®-DITRA-HEAT Installation Handbook. There are now double the number of cable lengths available for the Schluter-Systems DITRA-HEAT floor warming system. LVT), Uncoupling membrane for DITRA-HEAT-E-HK electric floor heating cables, Using a Prefabricated Shower Tray and Ramp, Continuing Education for Architects & Designers, Schluter®-DITRA-HEAT-E-HK Heating Cables are certified by CSA to CAN/CSA-C22.2 No.130-16 (Canada), Schluter®-DITRA-HEAT-E-HK Heating Cables are certified by CSA to UL 1673 (US), Schluter®-DITRA-HEAT-E-HK Heating Cables are listed by UL to UL 1683 (US) and CAN/CSA-C22.2 No. The DHEHK12043 is a twisted pair heating The DHEHK12043 is a twisted pair heating cable designed specifically for use with the Ditra-Heat membrane for interior floor warming applications. Warm Your Floor is an authorized Schluter dealer. Ditra-Heat-Duo is an uncoupling and waterproofing membrane designed to secure the Ditra-Heat heating cable in place. Only 1 left in stock - order soon. Installation. Proper installation results in full contact between the fleece webbing and the thin-set mortar. The DITRA-HEAT-E-HK heating cable is selected according to the size of the area to be heated. To help determine the proper heating cable size for your application, please review the Schluter®-DITRA-HEAT Calculation Sheet and use the DITRA-HEAT Online Calculator. Please refer to the Schluter®-DITRA-HEAT Installation Handbook below for complete DITRA-HEAT system instructions. The DHEHK12011 is a twisted pair heating cable designed specifically for use with the Ditra-Heat membrane for interior floor warming applications. DITRA prevents tiles and grout from cracking because of it’s geometric configuration.