The pressure switch tubing in one simple inexpensive part that I see break and fail many times during the winter months. R-79-21491 … Hope you can find an easy fix. Types Of Furnace Pressure Switches. 37. Repair your Lennox Furnace Hose, Tube & Fitting for less. No sir, a pressure switch should not hold moisture inside of it. We are Accredited Better Business Members with an A+ Rating! 1 … Since 1953. In the normal sequence of operations, if the pressure switch does not close during this preignition period, the control board will not allow the furnace to light. OneTrip Parts. You can disconnect the pressure switch tubeand run a wet vac to hopefully clear the stopped up furnace condensate drain line. X 18in ONETRIP Parts. 4.7 out of 5 stars 247. In-store: set your location. If the pressure switch is damaged, this could be the reason your furnace is malfunctioning. Model. 95. I hope you get lucky and that fixes the problem. Hope you have a great day! GTIN. It is very important to disconnect the pressure switch tubing from the inducer and other connections because using a wet vac or compressed air with the pressure switch tubing attached can damage the pressure switch. Seems air is drafting back down the exhaust tube from outside freezing the water in the drain pan when the furnace is not running. Any other ideas?? I think that it is worth a try. Problem: Water or moisture buildup in my pressure switch tube on my 80% furnace. Toggle menu. This answer is exactly right. $49.95 $ 49. I’m not sure how to fix this yet. Furnace Pressure Switch Not Closing. Before you start. (I told him I wanted to be cheap about the “fix”). It works great. If you have any other questions please email us support@arnoldservice.com or comment below. X 18in ONETRIP Parts. On 90% furnace, the drain is usually located near the bottom of the inducer and it will have a drain hose attached to it. Hi Scott! My pressure switch keeps shutting the furnace off. tubing is 18" long. That differential pressure switch is the combustion air proving switch, and has two tubes because it compares the exhaust and condensate trap air pressures. I would then either use a wet vac to suck the debris out of the condensate drain line or use compressed air to clear the stoppage so the condensate drain on the furnace can drain properly. We have one of the Best in Website Security with a Norton Symantec Secured Website and Shopping Cart! I am baffled why the water will not drain when a hose is attached. Fantastic! Get it as soon as … Thanks for the reply. Acuteye 50 FT Pneumatic Air line, 1/4 Od Nylon Tubing,Air Line 1/4 inch OD,1/4 Air Line,15 Meters Air Brake Tubing Nylon Air Hose for Air Brake System Or Fluid Transfer, Utah Pneumatic Air Line 1/4" Od 32.8 Feet 10 Meters SAEJ844 Air Brake Tubing Nylon Air Ride Hose DOT Approved for Air Brake System Or Fluid Transfer(Nylon Tube 1/4), Heavy Duty Air Pressure Control Switch, Sunny L4, 4 port, 95-125 PSI, 25 Amp, Aquatec 6800 Booster Pump Kit for up to 100 GPD home RO reverse osmosis water filter system Standard or Manifold, includes pump, pressure switch PSW-240, transformer, 6840-2J03-B224 B221 Made In USA, White SiliconeTubing, 3/16"ID, 5/16"OD, 1/16" Wall, 10' Length, ZHKUO 120W Water Pressure Booster Pump 1 inch Outlet Automatic Shower Booster Pump with Water Flow Switch for Home/Shower, Tailonz Pneumatic Blue 6mm OD 4mm ID Polyurethane PU Air Hose Pipe Tube Kit 10 Meter 32.8ft, Fantech DB 10 Pressure Switch Kit Only with Delay, bayite 12V DC Fresh Water Pump with 2 Hose Clamps 12 Volt Diaphragm Pump Self Priming Sprayer Pump with Pressure Switch 4.5 L/Min 1.2 GPM 80 PSI Adjustable for RV Camper Marine Boat Lawn, JEGS Brake Light Switch Kit | Includes Switch, Brass Tee Fitting, Heat Shrink Tubing and Wiring Pigtail, Digital Manometer, Dual Port Air Pressure Meter Pressure Gauge HVAC Gas Tester, Differential Pressure Manometer with 5/16 Inches Diameter Pressure Port, Hti-Xintai, Almencla Air Compressor Pressure Switch D55168 N003990 160 PSI Cut On/200 PSI Cut Off, Duda Energy HPpvc025-025ft 25' x 1/4" ID High Pressure Braided Clear Flexible PVC Tubing Heavy Duty UV Chemical Resistant Vinyl Hose, PLXparts 2 Pack Furnace Vent Air Pressure Switch - Replacement for Goodman 20197310, Tailonz Pneumatic Orange 1/4 Inch OD 10 Meters PU Air Tubing Pipe Hose Pu Air Hose for Air Line Tubing or Fluid Transfer Tubing, Utah Pneumatic Air Line 1/4" Od 50 Feet SAEJ844 Air Brake Tubing Nylon Air Ride Hose DOT Approved for Air Brake System Or Fluid Transfer(1/4" air hose 50 feet), bayite 12V DC Fresh Water Pressure Diaphragm Pump with Hose Clamps Self Priming Sprayer Pump with Pressure Switch 4 L/Min 1.0 GPM 80 PSI for RV Camper Marine Boat, 20197308 - Goodman OEM Furnace Replacement Air Pressure Switch, Garbage Disposal Air Switch Kit, Sink Top Switch for disposal, Stainless Steel Brushed, LONG/2.5" Button By CLEESINK, Craftsman Z-AC-0746 Compressor Pressure Switch, Tank Shutoff (TSO) Switch for Aquatec Booster Pumps, Neoteck 12V DC Water Pump Automatic Pressure Switch, 6L/Min 1.6 GPM 100PSI High Pressure Micro Diaphragm Pump for RV Camper Marine Boat Caravan Lawn, Pure Silicone Tubing - 1/2" ID x 5/8" OD - High Temp Kink-Free Hose Tube 500F (3 Feet), Sunny Heavy Duty Air Pressure Control Switch, L1, 1 Port, 95-125 PSI, 25 Amp, Square D By Schneider Electric 9013FHG42J59M1X Air Compressor Pressure Switch, AquaDance 7" Premium High Pressure 3-Way Rainfall Combo for The Best of Both Worlds - Enjoy Luxurious Rain Showerhead and 6-Setting Hand Held Shower Separately or Together - Chrome Finish - 3328, LG Electronics 6501EA1001R Washing Machine Sensor Switch Assembly, OLIGHT RWX Remote Switch Warrior X Dedicated Magnetic Fast Connected Remote Pressure Switch,Compatible with Warrior X, M2R,M2R Pro, Javelot Pro,with SKYBEN Battery Case, DGZZI Drip Irrigation Switch Valve 4PCS 1/2 Inch ID Universal Drip IrrigationShut-Off Valve Tubing Coupling Valve, Square D 135-175 PSI Air Compressor Pressure Switch Control Valve 9013FHG42J59M1X, Square D Pumptrol Pressure switch for compressed air compressor 9013FHG12J52M1X 95-125 psi With Unloader & On/Off Lever (Paks), Garbage Disposal Air Switch Spa Bathtub Air Switch Button Kit Chrome Hot Tub Garbage Disposer or Evolution Food Waste Equipment, VIVOSUN 4 inch Inline Duct Fan 100 CFM, HVAC Exhaust Intake Fan, Low Noise & Extra Long 5.5' Grounded Power Cord, Lefoo Pressure Switch Control 90-125psi 4 Port Heavy Duty 26 Amp for Air Compressor LF10A-4H-1-NPT1/4-90-125, 26 AMP PRESSURE SWITCH CONTROL AIR COMPRESSOR 95-125 PSI 4-PORT HEAVY DUTY FRONT COVER ON/OFF BUTTON, PureSec 2020 Low Pressure Switch 1/4-inch Tube O.D.Push to Connect Plastic Pump Switch for RODI System, Hooshing 12V 60W Micro Electric Diaphragm Water Pump Automatic Switch High Pressure Car Washing Spray Water Pump 0.8Mpa 5L/min, PetOde Dryer Vent Cleaner Kit Dryer Vent Vacuum Attachment Lint Remover Power Washer and Dryer Vent Vacuum Hose(Light Blue), Square D 95-125 PSI Air Compressor Pressure Switch Control Valve 9013FHG19J52M1X, GE WH12X10093 Washing Machine Pressure Switch, 50 Feet - 3/8" ID 1/2" OD Clear Vinyl Tubing Food Grade Multipurpose Tube for Beer Line, Kegerator, Wine Making, Aquaponics, Air Hose by Proper Pour, Utah Pneumatic 3/8"Od 10 Meter Tubing Nylon Air Hose Air Tubing Pipe Hose DOT Approved For Air Line Tubing Or Fluid Transfer Pneumatic Tubing (Nylon Tube 3/8), PLXparts Furnace Vent Air Pressure Switch - Replacement for Goodman 20197310, SNS Pneumatic Od 1/4" 10 Meters Orange Color PU Pneumatic Air Tubing Pipe Hose for Air line or Fluid Transfer, Lefoo Pressure Switch Control Air Compressor 140-175 Single Port Heavy Duty 26 Amp LF10A-1H-1-NPT1/4-140-175, DWYER A-481 Differential Pressure Switch, for USE with ADPS/EDPS HVAC, Installer KIT, 6 INCH PVC TUBING, Controls RSS-498-013 Air Pressure Switch by Andrews Corner. I hope you can easily fix this problem. Using a cloth and a wire brush, remove any blockages and dirt from the secondary exchanger and the inducer. Now im not sure which hose goes where. $11.95 $ 11. I had a issue with water in the tube was freezing at the point where the hose attaches to the black plastic drain pan directly under the burners. I am thinking that this is like a plumbing drain line where plumbing drains need to be vented for proper draining. 82. Furnace Vent Air Pressure Switch - Replacement for Rheem ClimaTek Gas Part # 42-24335-02. Awesome! OneTrip Parts Furnace Pressure Switch High Temp Tubing 3/16 I.D. Only 4 left in stock - order soon. When we’re troubleshooting a furnace pressure switch, we can do a few things. If the furnace is level or tilting back the water will stay in the secondary heat exchanger and can freeze up. I don’t know why it gets that cold in there. The inducer motor may not be coming up to … Every time I put the hose back on, it stops draining and will overflow along where the unit connects to the main air duct. The plunger may not be pulling in completely and may only bob around when the pressure builds up inside the furnace. If a pressure switch is not jumpered correctly, the furnace will not turn on at all. Refine Your Search. Make sure you are using at least 3/4 inch PVC and not anything smaller. Usually water comes out of the tube. This silicone rubber tubing is the direct replacement for many Rheem, Ruud, and Weatherking furnace models. I purchase furnace pressure switch tubing from our ICP (International Comfort Products) parts supplier. Thanks so much for sharing this. OneTrip Parts Furnace Pressure Switch High Temp Tubing 3/16 I.D. Video can be used to help with Coleman / Revolv furnace. This silicone rubber tubing is the direct replacement for many Rheem, Ruud, and Weatherking furnace models. 632427 - Nordyne Furnace Vent Air Pressure Switch - OEM Replacement. Many times the tube is plugged up with water. How to fix Pressure Switch open signal on M1M / M1G furnace. 99. The only explanation that I can think of would be that if the condensate drain is on the return side of the air handler, then the suction pressure of the blower will not allow the water to drain out because it is sucking the water back into the air handler. 4.8 out of 5 stars 36. Category (152) Automotive (71) Fitness & Sports (28) Appliances (7) Lawn & Garden (4) Home Improvement (2) Tools see more (1) Outdoor Living (1) TVs & Electronics. The tubes stop up with water and the furnaces shut down. Yank off the furnace covers and inspect the side panels in the burner area to find the manufacturer’s label. My remedy for solving this problem is to unstop the furnace’s condensate drain by first disconnecting the pressure switch sensing tube. 95. Sign in Register 0 Cart. We can take our manometer and make sure the inducer motor is creating the vacuum by hooking up the meter’s hose directly to the collection chamber that the pressure switch tubing is connected. It would be best to email me at our arnoldservice@gmail.com email address so I can give you a parts list. Thanks for asking this question. … I hope you can get your problem solved. Hi Eric! Get it by Tomorrow, Feb 24. Your recently viewed items and featured recommendations, Select the department you want to search in, All customers get FREE Shipping on orders over $25 shipped by Amazon, Plug-and-Play Switching for Instant Connectivity, Price and other details may vary based on size and color, OneTrip Parts Furnace Pressure Switch High Temp Tubing 3/16 I.D. Usually ships within 2 to 3 days. I would think that the minus would go to the combustion chamber because the draft inducer is supposed to be pulling negative air from the combustion chamber and out to the vent. … Hi Mike! I had the same problem, the reason was due to a tear in the diaphragm in the pressure switch which I found by taking it apart. If it is a worn out drain hose that is leaking, then this hose will need to be replaced with a new hose. I have also found this water drainage problem to occur on furnaces because the furnace’s condensate drain line is stopped up. X 18" Replaces Rheem Ruud Weatherking 79-21491-83, FREE Shipping on orders over $25 shipped by Amazon, Supco Red Air Tubing Hose for Furnace Pressure Switches 1/4" x 60" SSRT145, Red Air Tubing Hose for Furnace Pressure Switches 3/16" x 60" Supco SSRT3165, Supco Red Air Tubing Hose for Furnace Pressure Switches 1/8" x 60" SSRT185, SUPCO SSRT3165 Silicone Tubing, 5 Feet Length, Red, 3/16" Inside Diameter, 5/16" Outside Diameter, 20 psi Working Pressure, -100 Degree F to 500 Degree F, Tailonz Pneumatic Air Line 1/4 inch od Black Pneumatic Nylon Tube 32.8ft Air Brake Tubing Nylon Hose, 10 Feet - 3/16" ID 7/16" OD Clear Vinyl Tubing Food Grade Multipurpose Tube for Beer Line, Kegerator, Wine Making, Airline Tubing for Aquarium, Air Water Hose, Fuel Line, Aquatec (PSW260-00) Tank Shut Off Pressure Switch 60 PSI; 1/4" JG, S1-02435261000 - York OEM Furnace Replacement Air Pressure Switch, Sellerocity Kit Unloader Hose W/ 2 Nuts/Ferrule Combos 2 Insert 24 Inches of 1/4 OD Tubing Compatible With Campbell Hausfeld ST117801AV. Is the “-” hose go to the blower and the “+” hose go to combustion chamber? You’re seeing this ad based on the product’s relevance to your search query. Home > HVAC > Furnace Repair Parts > Furnace Air Pressure, Damper, & Door Switches > 98L78-9 Lennox Pressure Switch Tubing, 9", High Temperature. Search. Where is the water coming from and how do I fix this permanently? X 18" Replaces Rheem Ruud Weatherking 79-21491-83. Below we have a really good Youtube video which shows how to troubleshoot pressure switch problems. I am sorry that I do not know for sure on the answer to your question. The pressure switch is made to sense negative air pressure not air and water. 5.0 out of 5 stars 1. Best Sellers; Special Offers; Best Air compressors Online; Hoses for air compressors; high pressure air hoses; Furnace Pressure Switch High Temp Tubing 3/16 I.d. OneTrip Parts Furnace Pressure Switch High Temp Tubing 3/16 I.D. I would suggest trying to reposition the furnace so that the water drains out the front into the condensate drain line. We Provide Fast UPS Shipping! FREE Shipping by Amazon. Had the furnace for 10 years and started suddenly for no apparent reason. X 18" Onetrip Parts® Replaces Rheem Ruud Weatherking 79-21491-83. Tested the hose and no blockages. 4.6 out of 5 stars 162. Hi Don! Gas furnace pressure switch and tubing. X 18" Replaces Rheem Ruud Weatherking 79-21491-83. In the past month i had to fix the issue with the furnace not starting by removing the rubber tube from the sensor and blowing in it to clear obstruction. Thank you so much for offering this information about a torn pressure switch diaphragm that caused moisture build up! My pressure switch was high enough, but the location of the tube was below the drain. My remedy for solving this problem is to unstop the furnace’s condensate drain by first disconnecting the pressure switch sensing tube. Where is the drain on the inducer. Brand. i was expecting to find bugs and other stuff in there, to my surprise its ice. Get it as soon as Fri, Feb 26. Share - Furnace Pressure Switch High Temp Tubing 3/16 I.d. I tried to answer the question in our post. Gas pressure was correct and temp rise across heat exchanger was within range. Get it as soon as Fri, Feb 19. God bless you! shop in . Tried other hoses too. 4.6 out of 5 stars 54. If your pressure switch is stuck, it is most likely a problem in the running of the furnace. Remove the drain tubing and clean it properly by blowing out on it. The problem was a clogged drain from the inducer. You might have a stopped up furnace drain. 4.1 out of 5 stars 20. Regarding this, what happens when a furnace pressure switch goes bad? The furnace is working OK. Here’s how to check for a tripped or failed furnace pressure switch: Place an ohmmeter lead on both pressure switch terminals. Take that pressure switch hose off and put your manometer’s hose on the same port. Search. Fixing pressure switch problems or codes. Other problems that could cause the pressure switch to not open are a dirty blower wheel on the inducer. CURRENTLY SOLD OUT. This hole allowed flu gas to continue to pass through leaving moisture behind. Mine has/had a lot of water in it and it’s mounted much lower (floor plate) than the one shown in the video. It is very important to disconnect the pressure switch tubing from the inducer and other connections because using a wet vac or compressed air with the pressure switch tubing attached can damage the pressure switch . Blow the moisture out and out it back on and everything works I only find the happening on days when it either rains or snows. On high-efficiency condensing furnaces, the water drain line could be stopped up, causing a water back up and blockage in the pressure switch tube. In these furnaces, one hose connects the pressure switch to the draft inducer fan. I have an American Standard Freedom 90 Two Stage furnace. Thanks! Check the tubing from the inducer. Only 7 left in stock - order soon. $11.95 $ 11. I would then either use a wet vac to suck the debris out of the condensate drain line or use compressed air to clear the stoppage so the condensate drain on the furnace can drain properly. $47.99 $ 47. Inspect the Pressure Switch Hose Remove the main access panel on the front of the furnace. My switch is also mounted lower. Click to see full answer. Steve. "onetrip parts furnace pressure switch high temp tubing" & marketplace (192) Only. 4.6 out of 5 stars 66. I remove the rubber tube from the circulating fan, blow it out and put it back which solves the problem temporarily. There is one pressure switch with two hoses in single-stage condensing furnaces. I am sorry, but I do not know what could be causing the problem other than maybe you have a water leak in your vent pipe. If one tee does not work then try two tee’s to try and relieve some of the sucking pressure from the blower motor. Thank you so much for taking your time to post this valuable information. About this product. We would love to have your business! Had a furnace repair guy out and he said it is okay to leave it without a hose attached and just let it run down the side since there is a floor drain near the furnace. Remounted switch and hose to have slope back to spud. I am sorry, but I do not know for sure. Must have been installed this way. Our email is. UPC. The tubing connects to the pressure switch on one end and the hot draft inducer on the other end. We carry a huge range of brand name items that can be purchased online. We Have Promptly Shipped Over 350,000 Orders Since 2002! We sell many different types of pressure switches on the following page: Please click here to see the pressure switches we sell. Prime members enjoy FREE Delivery and exclusive access to music, movies, TV shows, original audio series, and Kindle books. At least now i know that i can jam a rod in the hole to clear the ice. My remedy for solving this problem is to unstop the furnace’s condensate drain by first disconnecting the pressure switch sensing tube. I’m not sure why this happens though. Your pressure switch then runs a diagnosis of your draft motor and begins moving heat … That why we stock genuine manufacturer furnace parts that are a perfect fit for your particular model, from igniters and flame sensors , to control boards , blower wheels, condensate traps, drain hoses , and pressure switch hoses. 98L78B - Pressure Switch TUBING 6IN LONG. I will give that a try! Required fields are marked *. 13. A small amount of water collects in the pressure switch tube of my gas furnace every week which is located in the basement, enough not to close the pressure switch and therefore causing the furnace to click ON and OFF continuously. Fast, same day shipping. It had lots of bugs and gunk. My little helper decided to pull the hoses off my pressure switch while i was removing my inducer motor. Air Conditioning Parts All Air Conditioning Parts A/C Cabinet Parts Accessories Install Accessories Whips / Disconnects Condenser Coils AC Covers Compressors Condensate Parts Evaporator Coils Fan Blades Fan Motors Line Driers … How to jump or bypass pressure switch on a furnace. Answer:  One or our customer wrote to us and said the following: “FYI, regarding moisture buildup in pressure tubes, I simply moved the pressure switch above where the tube connects to the inducer and the moisture problem went away (on both Goodman & Rheem furnaces)”. Sorry that I can not be more helpful! Shop for Supco Furnace Heating Parts and Supplies. After a few cycles it gets into the pressure switch nipple causing pressure switch failure on my furnace . Write down (or shoot a cell phone photo) of the model number, serial number and date of manufacture. Focus on the important things first before you change the gas furnace pressure switch. This part is covered by the exclusive OneTrip Parts two year limited … Get it as soon as Wed, Dec 2. I do not know if this is normal to have this much freezing happening inside the furnace. You could have a bad, dragging, dirty or slow running draft inducer.The tube that runs from your pressure switch to the draft inducer could be plugged up. Problem: I own several rental properties. $28.95 $ 28. Steve. Steve. 80% Trane furnace about 12 years old. About this product. Photo 1: Find model and serial numbers . I hope you have a nice day! It works- fantastic. OneTrip Parts Furnace Pressure Switch High Temp Tubing 3/16 I.D. I had the same problem with water in my pressure switch tube. We offer same-day shipping on most products, so you won’t have to do without the goods you need for long. Please help its freezing in my house. I do not know if you have a worn out leaking drain hose that is causing the water or if your furnace is not tilted properly and not allowing the water to drain correctly. Sorry that I do not have a definite solution to the problem. When i removed the pan to see what was going on inside, i found ice and water at the ends of what i think is the heat exchange tubes. FREE Shipping. HK06WC091 - Carrier OEM Furnace Replacement Air Pressure Switch . When you change your thermostat, you send a signal to your control board. Hi Chad! Steve, This was not helpfull at all evryone knows how to test pressure switches and 90 % of them on the market today are adjustable with a #1 square bit, my question was recuring moisture in the vaccuum hose ty, Sorry that I do not know the answer to your question. I have never seen a drain on an 80% furnace because the heat of the hot gas should burn the water out of the inducer. We would love to help you out and have your business! In this episode of Repair and Replace, Vance shows how to replace the pressure switch, which is part of troubleshooting a furnace that won't ignite. 0 items Toggle navigation. McCombs Supply Co., Fast Shipping. Your control board, in turn, checks the centrifugal switch to ensure it’s open and non-energized. Dust or dirt buildup that causes the switch to jam; Testing a Furnace Pressure Switch. This is how i found out about the ice. X 18" Replaces Rheem Ruud Wea… Your email address will not be published. FREE Shipping on orders over $25 shipped by Amazon. Any insight would be appreciated. Silicone Red Rubber Tubing 1/4”x5' SSRT145. The furnace keeps clicking which turns the burners ON and OFF repeatedly. The draft inducer gets really hot. The pressure switch is used to prove this draft by a connection, typically rubber or vinyl tubing, directly to the heat exchanger or to the inducer draft motor housing. Hi Artie! FREE Shipping by Amazon. HK06NB020 - OEM Upgraded Replacement for Carrier Furnace Dual Air Pressure Switch (Renewed) $48.44 $ 48. Steve. 44. Product Key Features. We sell furnace parts, air conditioning parts, AprilAire filters, EZ Flex filters, and many other HVAC parts and supplies at affordable prices. Is a pressure switch supposed to hold moisture? If your condensate trap starts leaking, the furnace will still operate if that tube isn't connected and that isn't a fail safe situation. Current fix, blocking the rubber tube to the top of the firing box that also connects to the gas pressure valve allows the pressure switch act normally. The pressure switch is an indicator of pressure problems in the furnace. Thanks, grayfurnaceman! The drain its self was not clogged, nor was there any water in the pan its self, just some accumulation of ice and water in the pipes where the strips of metal were. Furnace Vent Air Pressure Switch - Replacement for Rheem ClimaTek Gas Part # 42-24335-02. The 3/16 . Product Identifiers. Thanks! Oil Pressure Sensors Compatible with Chevy GMC... After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. Whether you need furnace ignitors, AprilAire filters, EZ Flex filters, or another kind of HVAC merchandise, we want to serve you. $29.13 $ 29. Very surprising. 95. The furnace can not drain properly so the water backs up in the draft inducer and pressure switch then there is a “pressure switch failed to close” error on the furnace’s control board flash code. The pressure switch is a small and useful component but can lead to many failures if not understood well. Steve. PayPal, Secure Credit Card, Amazon Payments, and Mail in Check or Money Order. If you ever experience a problem with any of your orders, contact us right away and we will make it right. Quality Furnace Hose, Tube & Fitting Parts From Repair Clinic Repair Clinic knows that having a fully-functioning furnace is essential when the temperature drops. If anyone needs a pressure switch we sell lots of pressure switches on the following page: https://arnoldserv.wpengine.com/product-category/pressure-switches/ Please send your furnace model number and I will try to find out which pressure switch your furnace uses. I hope you have a blessed day. My remedy for solving this problem is to unstop the furnace’s condensate drain by first disconnecting the pressure switch sensing tube. It should be clear. ( 12 or so tube outlets with a strip of metal inside each of them). I had replaced inducer several weeks ago. Pressure Switch 1.81 In.WC. Find Lennox Furnace Hose, Tube & Fitting Replacement Parts at RepairClinic.com. A furnace pressure switch is a safety device designed to sense the negative pressure created by the draft inducer at startup. The pressure sensors are above where the pressure tube attaches to the pan so the water did not actually freeze in the rubber tube but it froze inside the plastic outlet on the pan. If the pressure switch tube has water in it then this is a sign that your condensate drain line could be stopped up or not draining properly. I would like to suggest that you place a Tee fitting (Vent) in the drain line just outside where the condensate drain connects to the drain on your air handler. At this point I can’t get the furnace to come on at all.Thoughts? The furnace can not drain properly so the water backs up in the draft inducer and pressure switch then there is a “pressure switch failed to close” error on the furnace’s control board flash code.